2、系统参数与特性 |
 |
|
系统电源WRA12SX |
|
输入端口Input |
输入电压 Supply Voltage |
85…264VAC/80…350VDC |
|
|
选用 (Option) |
(19…140VDC) |
|
频率Frequency |
47…440Hz |
|
输出端口
Output |
输出电压Output Voltage |
12VDC |
|
输入功率Input Power |
25W, 2.1A |
|
绝缘
Insulation |
输入口/输出口Input/Output |
3000VAC, 1min |
|
输入/场合Input/case |
2500VAC, 1min |
|
输出/场合Output/case |
500VAC, 1min |
|
输入/输出/场合Input/Output/case |
50MW, 500VDC |
|
操作环境
Operating Environment |
操作温度Operating Temperature |
-5…+50°C |
|
储存温度Storage Temperature |
-20…+85°C |
|
相对温度Relative Humidity |
85% |
|
振动Vibration |
5…10Hz 10mm, 10…50Hz 2G |
|
撞击Blows |
10G |
|
尺寸Measurements |
97W*124L*33H |
|
重量Weight |
400g |
|
干扰测试Disturbance Tests |
与电磁兼容性标准一致Compliance with the EMC-standard |
|
其它认证Other Certification |
UL, CSA,VDE | |
 |
|
主单元UTU-Falcon Main Unit |
|
|
辅助电压Auxiliary Voltage |
12VDC |
|
功率损耗Power Consumption |
6W |
|
输入
Inputs |
16个弧光输入端口16 Photo Inputs |
可编程/跳闸(Programmable/trippings) |
|
4个弧光输入端口4 Photo Inputs |
可编程/跳闸(Programmable/trippings) |
|
4个数据传输端口4 Data Transmission Cables |
可以获取数据信息(Can be also used to take data out) |
|
输出
Outputs |
4个跳闸信号输出? 4 Tripping Circuits, triac 5A, 600Vp (25A<1s),*triac Irms="25A" Vdrm="600V" (Itsm=175A) |
可编程(Programmable) |
|
6个跳闸信号继电器输出口6 Tripping Circuits, Relay Output 5A, 250VAC |
自由电位式切换接点,可编程,也能延迟时间 (Potential-free change-over contact, programmable also to have time delay) |
|
1个弧光输出端口1 Photo Output |
其它系统的附加保护(Additional Protection for Other Systems) |
|
跳闸信号
Tripping Signal |
4个小于 1 ms
6个小于10 ms? |
可编程的跳闸速度(Length of Tripping Speed Programmable) |
|
显示
Display |
双色显示2-colour Led |
正常运行:绿灯Normal Function: green light
跳闸打开:绿光Tripping ON: green light
跳闸信号动作:红光、绿光闪动Tripping? is no longer ON: flashing red and green |
|
分7段显示7-segment Display |
正常运行/警报/跳闸(Normal Function/Alarm/Tripping) |
|
光灵敏度调节范围Adjustment of Sensitivity to Light |
10klx…50klx |
|
|
检测Tests |
EN50081-1, EN50082-2 |
依照电磁兼容性标准(Compliance with the EMC-Standard) |
|
|
DNV |
DNV认可 |
|
操作环境
Operating Environment |
操作温度Operating Temperature 0…+70°C |
|
储存温度Storage Temperature -25…+85°C |
|
尺寸Measurements(mm) |
hl 92* k 196* s 172 |
|
重量Weight |
1.7kg | |
 |
|
弧光检测辅助单元Falcon-ARC Arc Unit |
|
|
辅助电压Auxiliary Voltage |
12VDC |
|
功率损耗Power Consumption |
1W |
|
输入端口
Inputs |
10个弧光输入端口10 Photo Inputs |
在主单元,每个输入端口都能被识别(In Main Unit, each input can be identified) |
|
1个数据传输通道1 Data Transmission Cable |
辅助电压,警报,自动调节(Auxiliary Voltage, Alarms, Self-control) |
|
输出端口
Outputs |
1个弧光输出口1 Photo Output |
跳闸信号,其它弧光检测辅助、过流检测辅助单元和主单元
(Tripping Signal, other Arc and Current Units and Main Unit) |
|
一个数据传输信道1 Data Transmission Cable |
辅助电压,警报,自动检测(Auxiliary Voltage, Alarms, Self-control) |
|
跳闸信号Tripping Signal |
小于 1 ms |
|
|
显示
Display |
双色显示2-colour Led |
正常运行:绿光Normal function: green light
警报:超过预置的照明值时显示红光Light alarm: red light when pre-setted of illuminance value is exceeded
警报:闪烁红光Light alarm: flashing red: no longer light |
|
光灵敏度的调整范围Adjustment of Sensitivity to Light |
10klx…50klx |
|
|
开关功能键
Switches |
重置reset |
弧光检测辅助单元重置(Reset of Arc Unit) |
|
测试test |
进行编程。测试时按住按钮5秒钟(Programmed to same switch with reset. Push the button 5 second when? testing) |
|
检测Tests |
EN50081-1, EN50082-2 |
依照电磁兼容性标准(Compliance with the EMC standard) |
|
|
DNV |
DNV认可 |
|
操作环境Operating Environment |
操作温度Operating Temperature 0…+70°C |
|
储存温度Storage Temperature? -25…+85°C |
|
尺寸Measurements(mm) |
h 160* k 105* s 44 |
|
重量Weight |
0.7kg | |
 |
|
过流检测辅助单元Falcon-CR Current Unit |
|
|
辅助电压Auxiliary Voltage |
12VDC |
|
功率损耗Power Consumption |
1W |
|
输入端口
Inputs |
5A, 2A and 1Al |
有5A, 2A 和1A的不同接线端口(Current Unit has 5A, 2A and 1A measuring coils) |
|
1个数据传输信道1 Data Transmission Cable |
辅助电压,警报,自动检测(Auxiliary Voltage, Alarms, Self-control) |
|
输出端口
Outputs |
1个弧光输出端口1 Photo Output |
跳闸,其它弧光检测辅助、过流检测辅助单元和主单元(Tripping Signal, to other Arc and Current Units and Main Units) |
|
一个数据传输端口1 Data Transmission Cable |
辅助电压,警报,自动检测(Auxiliary Voltage, Alarms, Self-control) |
|
跳闸信号Tripping Signal |
小于 1 ms |
|
|
显示
Display |
双色显示2-colour Led |
正常运行:绿光Normal function: green light
过流警报:超过预置的电流量时显示红光
Current alarm: red light when pre-setted current valuue is exeeded
警报:闪红光:不再过电流
Light alarm: flashing red: no longer over current |
|
预置过电流范围
Pre-setting of Current |
50…500%*In |
|
|
开关功能键
Switches |
重置reset |
弧光检测辅助单元重置(Reset of Current Unit) |
|
测试test |
进行编程。测试时按住按钮5秒钟(Programmably set in the same switch with the reset button. When carrying out the test, the button shall be pressed for 5s continuously.) |
|
检测Tests |
EN50081-1, EN50082-2 |
依照电磁兼容性标准(Compliance with the EMC standard) |
|
|
DNV |
DNV’s 认可 |
|
操作环境Operating Environment |
操作温度Operating Temperature 0…+70°C |
|
储存温度Storage Temperature -25…+85°C |
|
尺寸Measurements(mm) |
h 160*k 105*s 44 |
|
重量Weight |
0.9kg | |
 |
|
光纤线缆 HFBR-EUS |
|
环境温度 |
短期 |
-25 + 85°C |
|
持续 |
-25 + 75°C |
|
弯曲半径 |
安装期间 |
min. 15mm |
|
安装后 |
min. 25mm | |